Player cannot open a remote session
- Confirm Global Settings for CICS/MQ or IMS Connect are saved (host + channel + queue manager, or host + data store).
- Select an operation that has descriptors (Import maps, mainframe, AtomIQ, or example).
- For CICS, start the target transaction (for example AQ00) on the mainframe before Play.
- For IMS, set Play start (Entry MID / Trancode) on the operation or in My Maps.
- Only one remote session per process — Close session on HTTP 409 / busy, or wait 15 minutes for idle release.
Screens look wrong or fields misaligned
- Re-import maps and re-OPEN Player — descriptors are not hot-reloaded.
- For CICS, the symbolic copybook must match the BMS map (one map per BMS file).
- For IMS, each
.mfsfile must contain exactly one MID and one MOD.
Import from mainframe or AtomIQ fails
- Save Global Settings first, then Test connection. AtomIQ Test uses the stored password only.
- JZOS Test authenticates the user; catalog and member reads run as the USS process identity.
- Stay within 50 selected members (mainframe) or 50 MiB for an
.atqupload.
AI features not working
- Configure an AI provider with a model name and a valid API key under Global Settings.
- For local models, select Ollama and set the custom URL (default
http://localhost:11434).
Session busy, misaligned screens, import Test, and AI setup.